The Blue M Ultra-Temp® Inert Gas High-Temperature Oven, pressure tested at operating temperatures, is suitable for all inert gases and non-flammable forming gases (maximum 4% hydrogen, balance nitrogen).
Available Oven Options
- Stainless steel shelves
- 24-hour, 7-day digital process timer
- Trace oxygen analyzer
- Temperature recorders (paper or paperless)
- Reverse door hinge
- Swivel casters with leveling feet
- Programmable controller, Ethernet and USB communications
- Data logging and trending
- Variable frequency drive on circulation blower
- Lead-in ports (various locations available)
- Electro-mechanical or pneumatic door lock
- Emergency Power Off Pushbutton
- Emergency stop
- Light tower assembly with audible alarm
- Maintenance lock-out system
- Main power fused disconnect switch
- Redundant over-temperature protection (high limit controller)
- UL508A labeled control panel
- CE Mark
- Motorized exhaust damper (two-position or proportional)
- Alternative exterior finishes
For a full list of available options click here.
GENERAL SPECIFICATIONS | ||
---|---|---|
Temperature range | 15°C (27°F) above ambient to 593°C (1100°F) | |
Controller accuracy | +/- 1.0°C (+/- 1.8°F) | |
Controller resolution | +/- 0.1°C (+/- 0.1°F) | |
Workspace capacity | 4.2 to 24.0 cubic feet | |
Uniformity | Blue M can provide varying levels of uniformity; if you have a specific tolerance or specification which must be met, please contact us with your requirements so we can ensure the equipment is designed, tested, and adjusted to meet those requirements |
DIMENSIONAL SPECIFICATIONS | ||||
---|---|---|---|---|
Model | 6680 | 7780 | 8880 | 9980 |
Interior Volume | 4.2 cu. ft. | 5.8 cu. ft. | 11.0 cu. ft. | 24.0 cu. ft. |
Interior Dimensions WxDXH in. (cm) |
20 x 18 x 20 (50.8 x 45.72 x 50.8) |
25 x 20 x 20 (63.5 x 50.8 x 50.8) |
38 x 20 x 25 (96.52 x 50.8 x 63.5) |
48 x 24 x 36 (121.92 x 60.96 x 91.44) |
Exterior Dimensions WxDXH in. (cm) |
46 x 36 x 72 (116.84 x 91.44 x 182.9) |
51 x 38 x 74 (129.5 x 96.52 x 188) |
84 x 39 x 77 (213.4 x 99.1 x 195.6) |
96 x 43 x 83 (243.84 x 109.22 x 210.8) |
Machine Footprint | 11.5 sq. ft. | 13.5 sq. ft. | 23.0 sq. ft. | 28.7 sq. ft. |
ELECTRICAL SERVICE | ||||
---|---|---|---|---|
208 VAC 3 Ph 60 Hz Line current (Amps) |
12.0 kW (38) |
15.7 kW (47) |
18.8 kW (56) |
22.5 kW |
240 VAC 3 Ph 60 Hz Line current (Amps) |
16.0 kW (43) |
21.0 kW (53) |
25.0 kW (64) |
30.0 kW (82) |
480 VAC 3 Ph 60 Hz Line current (Amps) |
16.0 kW (20) |
21.0 kW (27) |
25.0 kW (32) |
30.0 kW (40) |
Please contact the factory to inquire on engineered to order options.
The Blue M Ultra-Temp® Inert Gas High-Temperature Oven, pressure tested at operating temperatures, is suitable for all inert gases and non-flammable forming gases (maximum 4% hydrogen, balance nitrogen).
Available Oven Options
- Stainless steel shelves
- 24-hour, 7-day digital process timer
- Trace oxygen analyzer
- Temperature recorders (paper or paperless)
- Reverse door hinge
- Swivel casters with leveling feet
- Programmable controller, Ethernet and USB communications
- Data logging and trending
- Variable frequency drive on circulation blower
- Lead-in ports (various locations available)
- Electro-mechanical or pneumatic door lock
- Emergency Power Off Pushbutton
- Emergency stop
- Light tower assembly with audible alarm
- Maintenance lock-out system
- Main power fused disconnect switch
- Redundant over-temperature protection (high limit controller)
- UL508A labeled control panel
- CE Mark
- Motorized exhaust damper (two-position or proportional)
- Alternative exterior finishes
For a full list of available options click here.
GENERAL SPECIFICATIONS | ||
---|---|---|
Temperature range | 15°C (27°F) above ambient to 593°C (1100°F) | |
Controller accuracy | +/- 1.0°C (+/- 1.8°F) | |
Controller resolution | +/- 0.1°C (+/- 0.1°F) | |
Workspace capacity | 4.2 to 24.0 cubic feet | |
Uniformity | Blue M can provide varying levels of uniformity; if you have a specific tolerance or specification which must be met, please contact us with your requirements so we can ensure the equipment is designed, tested, and adjusted to meet those requirements |
DIMENSIONAL SPECIFICATIONS | ||||
---|---|---|---|---|
Model | 6680 | 7780 | 8880 | 9980 |
Interior Volume | 4.2 cu. ft. | 5.8 cu. ft. | 11.0 cu. ft. | 24.0 cu. ft. |
Interior Dimensions WxDXH in. (cm) |
20 x 18 x 20 (50.8 x 45.72 x 50.8) |
25 x 20 x 20 (63.5 x 50.8 x 50.8) |
38 x 20 x 25 (96.52 x 50.8 x 63.5) |
48 x 24 x 36 (121.92 x 60.96 x 91.44) |
Exterior Dimensions WxDXH in. (cm) |
46 x 36 x 72 (116.84 x 91.44 x 182.9) |
51 x 38 x 74 (129.5 x 96.52 x 188) |
84 x 39 x 77 (213.4 x 99.1 x 195.6) |
96 x 43 x 83 (243.84 x 109.22 x 210.8) |
Machine Footprint | 11.5 sq. ft. | 13.5 sq. ft. | 23.0 sq. ft. | 28.7 sq. ft. |
ELECTRICAL SERVICE | ||||
---|---|---|---|---|
208 VAC 3 Ph 60 Hz Line current (Amps) |
12.0 kW (38) |
15.7 kW (47) |
18.8 kW (56) |
22.5 kW |
240 VAC 3 Ph 60 Hz Line current (Amps) |
16.0 kW (43) |
21.0 kW (53) |
25.0 kW (64) |
30.0 kW (82) |
480 VAC 3 Ph 60 Hz Line current (Amps) |
16.0 kW (20) |
21.0 kW (27) |
25.0 kW (32) |
30.0 kW (40) |
Please contact the factory to inquire on engineered to order options.
Features & Benefits
Features
- Approved for Argon, Carbon Dioxide, Helium, and Nitrogen inert gases
- Open-air heavy-gauge nichrome wire heater elements
- Unique inner/outer shell chamber allows coolant ambient air to circulate around an inert gas inner chamber
- Intake blower motor
- Gas flow and chamber pressure monitor and regulator on the control panel
- A high volume horizontal airflow system
- 6 inches of Mineral wool insulation
- Blue M tadpole door gasket design
- 3/8 inch inlet connection
- Exhaust port and damper
- Pressure Relief Valve
- Purge timer
- Heat Enable light
- Water-Cooled Door on IGF models 8880 and 9980
Benefits
- Welded and sealed inner chamber eliminates fume migration into the insulation
- Prevents oxidation on product
- Alerts operator of loss of airflow and shuts down oven heaters to minimize unwanted results
- Ensures safety of operators with a door switch that shuts down heaters and blower when the door opens
Application & Industries
Applications
- Aging
- Annealing
- ASTM Testing
- Curing
- Drying
- Photo Resist
- Solvents, Coatings, and Paint Curing
- Stress-Relief