Product details
The Blue M Inert Gas Mechanical Convection Oven, which we pressure-test at normal operating levels, is ideal for industrial oven applications that involve curing, heat treating, and packaging of electronic components as well as other applications which require a controlled atmosphere environment.
Available Oven Options
- Nickel-plated wire rod or stainless steel slotted shelves
- 24-hour, 7-day digital process timer
- Temperature recorders (paper or paperless)
- Reverse door hinge
- Floor stands (bench models only)
- Swivel casters with leveling feet
- Programmable controller, Ethernet, and USB communications
- Data logging and trending
- Variable frequency drive on circulation blower
- Exclusive, adjustable, semi-pierced duct walls for tuning of airflow
- Lead-in ports (various locations available)
- Electro-mechanical or pneumatic door lock
- Emergency stop pushbutton
- Light tower assembly with audible alarm
- Maintenance lock-out system
- Main power fused disconnect switch
- Redundant over-temperature protection (high limit controller)
- UL508A labeled control panel
- Alternative exterior finishes
- CE Mark
- HEPA Filtration with DCCI Models
- Dual Gas System
- Trace Oxygen transmitter
- N2 Run Valve
- Low N2 Pressure Switch with Alarm
- High O2 Alarm Indicator (pilot light) with Alarm Silence switch
- Under Temperature Protection
- Alarm Silence / End of Process Pushbutton Light
For a full list of available options click here.
GENERAL SPECIFICATIONS | ||
---|---|---|
Temperature range | 15°C (27°F) above ambient to 350°C (662°F) | |
Controller accuracy | +/- 1.0°C (+/- 1.8°F) | |
Controller resolution | +/- 0.1°C (+/- 0.1°F) | |
Workspace capacity | 4.2 to 24.0 cubic feet | |
Heat up time |
350°C (662°F) 60 minutes or less depending on model and voltage, empty chamber |
|
Uniformity | Blue M can provide varying levels of uniformity; if you have a specific tolerance or specification that must be met, please contact us with your requirements so we can ensure the equipment is designed, tested, and adjusted to meet those requirements |
DIMENSIONAL SPECIFICATIONS | |||||
---|---|---|---|---|---|
Model | DCI-206 (Bench Model) |
DCI-256 (Bench Model) |
DCI-296 (Floor Model) |
DCI-336 (Floor Model) |
DCI-1406 (Floor Model) |
Cubic Feet (Liters) | 4.2 (119) | 5.8 (164) | 9 (255) | 11 (312) | 24 (680) |
Interior Dimensions WxDxH in(mm) |
20 x 18 x 20 (508 x 457 x 508) |
25 x 20 x 20 |
25 x 25 x 25 (635 x 635 x 635) |
25 x 20 x 38 (635 x 508 x 965) |
48 x 24 x 36 (1219 x 610 x 914) |
Exterior Dimensions WxDxH in(mm) |
42 x 34 x 56 (1067 x 864 x 1423) |
47 x 36 x 56 |
47 x 40 x 70 (1194 x 1016 x 1778) |
47 x 36 x 83 (1194 x 914 x 2109) |
70 x 40 x 81 (1778 x 1016 x 2058) |
Machine Footprint (sq. ft.) | 9.9 | 11.8 | 13.1 | 11.8 | 19.5 |
Approx Unit Weight (lbs) | 600 | 700 | 850 | 900 | 1350 |
ELECTRICAL SPECIFICATIONS | |||||
---|---|---|---|---|---|
208 VAC 1 Ph 60 Hz Heater KW Line current (Amps) |
3 (17) |
4.5 |
6 |
6 (35) |
6.8 (38) |
240 VAC 1 Ph 60 Hz Heater KW Line current (Amps) |
4 (20) |
6 (29) |
8 (40) |
8 (40) |
9 (44) |
208 VAC 3 Ph 60 Hz Heater KW Line current (Amps) |
6.8 |
9 (27) |
13.5 (40) |
13.5 (40) |
18 (53) |
240 VAC 3 Ph 60 Hz Heater KW Line current (Amps) |
9 (23) |
12 (31) |
18 (46) |
18 (46) |
24 (61) |
480 VAC 3 Ph 60 Hz Heater KW Line current (Amps) |
9 (12) |
12 (16) |
18 (23) |
18 (23) |
24 (31) |
The Blue M Inert Gas Mechanical Convection Oven, which we pressure-test at normal operating levels, is ideal for industrial oven applications that involve curing, heat treating, and packaging of electronic components as well as other applications which require a controlled atmosphere environment.
Available Oven Options
- Nickel-plated wire rod or stainless steel slotted shelves
- 24-hour, 7-day digital process timer
- Temperature recorders (paper or paperless)
- Reverse door hinge
- Floor stands (bench models only)
- Swivel casters with leveling feet
- Programmable controller, Ethernet, and USB communications
- Data logging and trending
- Variable frequency drive on circulation blower
- Exclusive, adjustable, semi-pierced duct walls for tuning of airflow
- Lead-in ports (various locations available)
- Electro-mechanical or pneumatic door lock
- Emergency stop pushbutton
- Light tower assembly with audible alarm
- Maintenance lock-out system
- Main power fused disconnect switch
- Redundant over-temperature protection (high limit controller)
- UL508A labeled control panel
- Alternative exterior finishes
- CE Mark
- HEPA Filtration with DCCI Models
- Dual Gas System
- Trace Oxygen transmitter
- N2 Run Valve
- Low N2 Pressure Switch with Alarm
- High O2 Alarm Indicator (pilot light) with Alarm Silence switch
- Under Temperature Protection
- Alarm Silence / End of Process Pushbutton Light
For a full list of available options click here.
GENERAL SPECIFICATIONS | ||
---|---|---|
Temperature range | 15°C (27°F) above ambient to 350°C (662°F) | |
Controller accuracy | +/- 1.0°C (+/- 1.8°F) | |
Controller resolution | +/- 0.1°C (+/- 0.1°F) | |
Workspace capacity | 4.2 to 24.0 cubic feet | |
Heat up time |
350°C (662°F) 60 minutes or less depending on model and voltage, empty chamber |
|
Uniformity | Blue M can provide varying levels of uniformity; if you have a specific tolerance or specification that must be met, please contact us with your requirements so we can ensure the equipment is designed, tested, and adjusted to meet those requirements |
DIMENSIONAL SPECIFICATIONS | |||||
---|---|---|---|---|---|
Model | DCI-206 (Bench Model) |
DCI-256 (Bench Model) |
DCI-296 (Floor Model) |
DCI-336 (Floor Model) |
DCI-1406 (Floor Model) |
Cubic Feet (Liters) | 4.2 (119) | 5.8 (164) | 9 (255) | 11 (312) | 24 (680) |
Interior Dimensions WxDxH in(mm) |
20 x 18 x 20 (508 x 457 x 508) |
25 x 20 x 20 |
25 x 25 x 25 (635 x 635 x 635) |
25 x 20 x 38 (635 x 508 x 965) |
48 x 24 x 36 (1219 x 610 x 914) |
Exterior Dimensions WxDxH in(mm) |
42 x 34 x 56 (1067 x 864 x 1423) |
47 x 36 x 56 |
47 x 40 x 70 (1194 x 1016 x 1778) |
47 x 36 x 83 (1194 x 914 x 2109) |
70 x 40 x 81 (1778 x 1016 x 2058) |
Machine Footprint (sq. ft.) | 9.9 | 11.8 | 13.1 | 11.8 | 19.5 |
Approx Unit Weight (lbs) | 600 | 700 | 850 | 900 | 1350 |
ELECTRICAL SPECIFICATIONS | |||||
---|---|---|---|---|---|
208 VAC 1 Ph 60 Hz Heater KW Line current (Amps) |
3 (17) |
4.5 |
6 |
6 (35) |
6.8 (38) |
240 VAC 1 Ph 60 Hz Heater KW Line current (Amps) |
4 (20) |
6 (29) |
8 (40) |
8 (40) |
9 (44) |
208 VAC 3 Ph 60 Hz Heater KW Line current (Amps) |
6.8 |
9 (27) |
13.5 (40) |
13.5 (40) |
18 (53) |
240 VAC 3 Ph 60 Hz Heater KW Line current (Amps) |
9 (23) |
12 (31) |
18 (46) |
18 (46) |
24 (61) |
480 VAC 3 Ph 60 Hz Heater KW Line current (Amps) |
9 (12) |
12 (16) |
18 (23) |
18 (23) |
24 (31) |
Features & Benefits
Features
- All-welded and sealed construction assures continuously low oxygen levels
- Door switch (disables heat and circulation blower upon door opening)
- Adjustable inert gas purge system including a flowmeter, two-way gas control valve, cycle start-up high flow purge, low flow adjustment, chamber pressure gauge, and supply connection. This feature allows for consistently low oxygen
- PPM levels within the work chamber
- Adjustable shelf levels
- Fiberglass insulation to ensure safe cabinet skin temperature
- Heavy-duty door - double-wall, insulated construction
- Independent, over-temperature protection (high limit controller) included
- Corrosion-resistant, all welded and sealed, stainless steel (type 304) interior
- All-welded, heavy-duty exterior with heavy-gauge, reinforced, cold-rolled steel
- Baked on white powder-coated enamel finish on the exterior for long-lasting corrosion protection
- Every oven is fully assembled and individually factory tested
- Circuit breaker provided for ground fault protection as standard
- Single or three-phase operation available in 50 Hz or 60 Hz
The following inert gases are approved for these ovens:
- Argon
- Carbon Dioxide
- Helium
- Nitrogen
Benefits
- High-quality design and simple operation
- Prevents oxidation
- Impervious barrier between the process chamber and the insulation material
- Easily maintain inert atmosphere
- Horizontal air flow assures uniform thermal performance under all loading conditions
- Differential Air Pressure Switches alert you if loss of pressure or airflow is detected
- Multiple model options for custom test needs
- Quick access for simple inner chamber cleaning
- Easy to use controller