Product details
Blue M Friction Aire® industrial safety ovens provide a controlled heat source without heating elements, which eliminates atmospheric explosions and ignitions when working with hazardous Class 1, Group D materials. Class 1 atmospheres contain flammable vapors, and Group D materials include many solvents commonly used in finishing applications, such as lacquers and paints.
Contact us today or ask an expert if you have any questions!
Typical Performance
(Only data differing from typical models is noted under additional models)
SPECIFICATIONS | |||
---|---|---|---|
Model | HS-1002, HS-1202, and HS-3802 (Typical) | HS-362 | HS-1004, HS-1204, and HS-3804 |
Temperature range | 20°C above ambient to 150°C (302°F) | -- | +20°C above ambient to +260°C (500°F) |
Uniformity | +100°C: 0.5°C | +150°C: 1.0°C | +200°C: 1.0°C |
Run up time to | +150°C: 120 minutes | +150°C: 60 minutes | +260°C: 140 minutes |
Cool down time to | +50°C: 30 minutes depending on ambient temperature | +50°C: 30 minutes depending on ambient temperature | +50°C: 30 minutes depending on ambient temperature |
Control accuracy | 0.5°C | -- | -- |
Approval | UL listed | Not UL listed | Not UL listed |
Drift |
+50°C: 1.0°C, +100°C: 0.75°C, +150°C: 0.50°C |
-- | +200°C: 0.50°C |
Maximum Velocity | 400 / FPM | 500 / FPM | 500 / FPM |
Minimum Velocity | 100 / FPM | 200 / FPM | 250 / FPM |
DIMENSIONAL SPECIFICATIONS | ||||||
---|---|---|---|---|---|---|
Model | Inside Dimensions inches (cm) W x D x H |
Overall Dimensions inches (cm) W x D x H |
HP | 1Approx Heating Power (Watts) | Cubic Feet Capacity | Shipping Weight Lbs. (Kg) |
HS-1002 | 14 x 17 x 12 (35 x 43 x 31) |
37 x 33 x 48 (93 x 84 x 120) |
1 | 500 | 1.3 | 465 (211) |
HS-1202 | 25 x 20 x 20 (63 x 51 x 51) |
42 x 39 x 63 (106 x 98 x 159) |
2 | 1300 | 5.2 | 800 (363) |
HS-3802 | 38 x 25 x 25 (95 x 63 x 63) |
57 x 44 x 68 (144 x 111 x 172) |
3 | 2000 | 13.7 | 1300 (590) |
1 Voltage - all models: 208/240/480 V 3-Phase / 60Hz. AC Chambers will operate satisfactorily on 208 V 3-Phase / 60Hz. AC when motor is connected for 240 V 3-Phase /60Hz AC
DIMENSIONAL SPECIFICATIONS | ||||||
---|---|---|---|---|---|---|
Model | Inside Dimensions inches (cm)W x D x H |
Overall Dimensions inches (cm) W x D x H |
HP | 1Approx Heating Power (Watts) | Cubic Feet Capacity | Shipping Weight Lbs. (Kg) |
HS-362-12 | 37 x 37 x 48 (93 x 93 x 120) |
66 x 58 x 91 (167 x 147 x 231) |
10 | 6500 | 36 | 2200 (1000) |
1 Voltage -all models: 208/240/480 V 3- Phase/ 60Hz. AC Chambers will operate satisfactorily on 208 V 3-Phase / 60Hz. AC when motor is connected for 240 V3-Phase /60Hz. AC
2 Bench Model
DIMENSIONAL SPECIFICATIONS | ||||||
---|---|---|---|---|---|---|
Model | Inside Dimensions inches (cm) W x D x H |
Overall Dimensions inches (cm) W x D x H |
HP | 1Approx Heating Power (Watts) | Cubic Feet Capacity | Shipping Weight Lbs. (Kg) |
HS-1004-1 | 14 x 17 x 12 (35 x 43 x 31) |
37 x 33 x 48 (93 x 84 x 120) |
1 | 600 | 1.3 | 465 (211) |
HS-1204-1 | 25 x 20 x 20 (63 x 51 x 51) |
42 x 39 x 63 (106 x 98 x 159) |
3 | 2000 | 5.2 | 800 (363) |
HS-3804-1 | 38 x 25 x 25 (95 x 63 x 63) |
57 x 44 x 68 (144 x 111 x 172) |
5 | 3000 | 13.7 | 1300 (590) |
Voltage -all models: 208/240/480 V 3-Phase/ 60Hz AC Chambers will operate satisfactorily on 208 V 3-Phase / 60Hz AC when motor is connected for 240 V 3-Phase /60Hz AC
Blue M Friction Aire® industrial safety ovens provide a controlled heat source without heating elements, which eliminates atmospheric explosions and ignitions when working with hazardous Class 1, Group D materials. Class 1 atmospheres contain flammable vapors, and Group D materials include many solvents commonly used in finishing applications, such as lacquers and paints.
Contact us today or ask an expert if you have any questions!
Typical Performance
(Only data differing from typical models is noted under additional models)
SPECIFICATIONS | |||
---|---|---|---|
Model | HS-1002, HS-1202, and HS-3802 (Typical) | HS-362 | HS-1004, HS-1204, and HS-3804 |
Temperature range | 20°C above ambient to 150°C (302°F) | -- | +20°C above ambient to +260°C (500°F) |
Uniformity | +100°C: 0.5°C | +150°C: 1.0°C | +200°C: 1.0°C |
Run up time to | +150°C: 120 minutes | +150°C: 60 minutes | +260°C: 140 minutes |
Cool down time to | +50°C: 30 minutes depending on ambient temperature | +50°C: 30 minutes depending on ambient temperature | +50°C: 30 minutes depending on ambient temperature |
Control accuracy | 0.5°C | -- | -- |
Approval | UL listed | Not UL listed | Not UL listed |
Drift |
+50°C: 1.0°C, +100°C: 0.75°C, +150°C: 0.50°C |
-- | +200°C: 0.50°C |
Maximum Velocity | 400 / FPM | 500 / FPM | 500 / FPM |
Minimum Velocity | 100 / FPM | 200 / FPM | 250 / FPM |
DIMENSIONAL SPECIFICATIONS | ||||||
---|---|---|---|---|---|---|
Model | Inside Dimensions inches (cm) W x D x H |
Overall Dimensions inches (cm) W x D x H |
HP | 1Approx Heating Power (Watts) | Cubic Feet Capacity | Shipping Weight Lbs. (Kg) |
HS-1002 | 14 x 17 x 12 (35 x 43 x 31) |
37 x 33 x 48 (93 x 84 x 120) |
1 | 500 | 1.3 | 465 (211) |
HS-1202 | 25 x 20 x 20 (63 x 51 x 51) |
42 x 39 x 63 (106 x 98 x 159) |
2 | 1300 | 5.2 | 800 (363) |
HS-3802 | 38 x 25 x 25 (95 x 63 x 63) |
57 x 44 x 68 (144 x 111 x 172) |
3 | 2000 | 13.7 | 1300 (590) |
1 Voltage - all models: 208/240/480 V 3-Phase / 60Hz. AC Chambers will operate satisfactorily on 208 V 3-Phase / 60Hz. AC when motor is connected for 240 V 3-Phase /60Hz AC
DIMENSIONAL SPECIFICATIONS | ||||||
---|---|---|---|---|---|---|
Model | Inside Dimensions inches (cm)W x D x H |
Overall Dimensions inches (cm) W x D x H |
HP | 1Approx Heating Power (Watts) | Cubic Feet Capacity | Shipping Weight Lbs. (Kg) |
HS-362-12 | 37 x 37 x 48 (93 x 93 x 120) |
66 x 58 x 91 (167 x 147 x 231) |
10 | 6500 | 36 | 2200 (1000) |
1 Voltage -all models: 208/240/480 V 3- Phase/ 60Hz. AC Chambers will operate satisfactorily on 208 V 3-Phase / 60Hz. AC when motor is connected for 240 V3-Phase /60Hz. AC
2 Bench Model
DIMENSIONAL SPECIFICATIONS | ||||||
---|---|---|---|---|---|---|
Model | Inside Dimensions inches (cm) W x D x H |
Overall Dimensions inches (cm) W x D x H |
HP | 1Approx Heating Power (Watts) | Cubic Feet Capacity | Shipping Weight Lbs. (Kg) |
HS-1004-1 | 14 x 17 x 12 (35 x 43 x 31) |
37 x 33 x 48 (93 x 84 x 120) |
1 | 600 | 1.3 | 465 (211) |
HS-1204-1 | 25 x 20 x 20 (63 x 51 x 51) |
42 x 39 x 63 (106 x 98 x 159) |
3 | 2000 | 5.2 | 800 (363) |
HS-3804-1 | 38 x 25 x 25 (95 x 63 x 63) |
57 x 44 x 68 (144 x 111 x 172) |
5 | 3000 | 13.7 | 1300 (590) |
Voltage -all models: 208/240/480 V 3-Phase/ 60Hz AC Chambers will operate satisfactorily on 208 V 3-Phase / 60Hz AC when motor is connected for 240 V 3-Phase /60Hz AC
Features & Benefits
Features
- High-velocity airflow system generates heat
- Blower creates air turbulence and friction for even heat
- Temperature-sensitive bellows regulates ambient air
- By-pass damper
- By-pass chamber
Benefits
- Controlled heat source eliminates atmospheric explosions and ignitions when working with Class 1, Group D materials
- Ideally suited for testing and processing of hazardous materials, paints, solvents, and lacquers.
- Maximum temperature uniformity
- Natural temperature interlock and built-in overtemperature protection provides added safety to users and product
- Economical design that endures years of use
Application & Industries
Applications
- Aging
- Annealing
- ASTM Testing
- Curing
- Drying
- Photo Resist
- Solvents, Coatings, and Paint Curing
- Stress-Relief